Edwards Est 3 Fire Panel Manual
Edwards EST3X is a next generation fire alarm system, with new multi-message displays, innovative controls, intuitive interface, new microprocessors and bold colors. The system follows with the EST3 architecture, having a robust modular control panel that unifies fire alarm, security and mass notification systems. The EST3X fire alarm system remains a leader in the field with the ability to have up to eight panels networked. Making the EST3X an ideal solution for mid to large size facilities. With intelligent devices throughout the network the EST3X system ensures uncompromising quality in the detection of fires in your building. The extensibility of smart devices through the field, plays a key role in the EST3X system in providing additional features such as security and mass notification.
Whether you have a new installation or an existing installation, the EST3X is capable of networking with up to 64 additional panels of an EST3 system. This makes the EST3X an ideal control panel for retrofits or additions.
Leveraging existing fire alarm system infrastructure is a great way to shorten time and costs of your projects. Silence In order to silence the EST3 or EST3X fire alarm system you need to determine if you will be performing an Alarm Silence or a Panel Silence. Panel Silence Panel silence is performed when the annunciator or main fire alarm panel are beeping. 2017 yamaha waverunner r 1200 service manual.
The beeping of the panel is local to either of these devices and there are no lights or horns generating noise throughout the building. This local beeping means there's a component that's currently in trouble. To silence the local beeping of the panel simply press the Panel Silence Button. When this button is pressed the green led next to the button will light up and the panel will stop making the sound. Please note that in the event new trouble conditions are generated by the panel, the local beeping will begin again and building personal will need to silence the panel once more.
Once the panel has been silence make sure to contact us to schedule a service technician to further investigate the issue with your system. Alarm Silence Alarm silence is performed when you need to silence the fire alarm system due to an alarm condition being detected. During an alarm conditions the strobes and horns/speakers in the building will be active.
Before performing the alarm silence for the building, security or maintenance personal should verify the alarm condition displayed on the panel, by investigating the physical location where the event is being reported. Once the event is confirmed as a false alarm the building personal can press the Alarm Silence button.
This will turn off the horn/speakers throughout the building, but the lights will continue to flash. Reset Panel reset is performed when you want the system to cycle through all devices and verify the states.
Edwards Est 3 Fire Alarm System
This is typically performed after an alarm condition, once the device that triggered the event has been reset. For example if a tenant activates a pull station in the building, maintenance personnel will need to reset the pull station back to the original position before using the reset function. Once all devices are set to the original state simply press the Rest button, the depending on the size of the system it might take a few minutes to receive the all clear. Once the system is clear all alarm audio and visual will be turned off in the building. System On Test Placing the system on test is usually performed when work is being done in a property that might accidentally trigger the fire alarm system in a building. While the system is on test if an alarm is triggered the horns/speakers and flashing lights will be triggered, but the fire alarm will not notify the fire department.
So its crucial if a fire event occurs during a test period, personnel notify the proper authorities in case of an actual emergency. To place the system in test you will need your account number, password and central station phone number. When you speak to one of our representatives you will need to give them the amount of time to place the system on test. Note there's a limit of 8 hours that a system can be on test.
Frequently Used Parts List. 202-7A-T 15/75 cd Synchronized Strobe, White. UL1971 Listed @ 15 cd (75 cd On Axis Per ADA/UL 1638), inchFIRE inch Wall Orientation. 270A-SPO Pull Station, Noncoded, Break Glass, Metal, Single Pole, Open Circuit, Wire Leads. 278B-1110 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Single Pole, Open Circuit, Screw Terminals, Wire Leads.
757-7A-SS70 15/75 cd Speaker/Strobe - 70V, Red. Strobe: UL 1971 Listed @ 15 cd (75 cd on-axis per ADA/UL1638), inchFIRE inch wall orientation. 757-7A-T 15/75 cd Temporal Horn/Strobe - 24 Vdc, Red. UL1971 Listed @ 15 cd (75 cd On Axis Per ADA/UL 1638), inchFIRE inch Wall Orientation.
757-8A-RS70 110 cd Re-entrant Speaker/Strobe - 70V, White. Strobe: Meets sleeping area requirement. UL 1971 Listed @ 110 cd, inchFIRE inch wall orientation.
757-8A-T 110 cd Temporal Horn/Strobe - 24 Vdc, Red. UL1971 Listed @ 110 cd, inchFIRE inch Wall Orientation. Meets Sleeping Area Requirements. CS405-8A-T Strobe w/TB EST G1F-HD Multi-cd temporal horn-strobe, hi/lo dB - 24V, White w/FIRE. G1F-HDVM Multi-cd temporal horn-strobe, hi/lo dB - 24V, White. G1F-VM Multi-cd strobe - 24V, White w/FIRE. G1RF-HDVM Multi-cd temporal horn-strobe, hi/lo dB - 24V, Red w/FIREe.
G4F-S7VM Speaker-strobe (70V), multi-tap, multi-cd, White w/FIRE. GCF-HDVM Ceiling mount horn-strobe, multi-cd (15/30/75/95cd), temporal hi/lo dB output, 24V - White w/FIRE. GCF-S7 Genesis Ceiling Speaker - 70V, FIRE marking, mounts to 4 inch square x 2-1/8 inch box. GCF-S7VM Genesis Ceiling Speaker-strobe - 70V, 15-95 multi-cd, FIRE marking, mounts to 4 inch square x 2-1/8 inch box. GCF-VM Genesis Ceiling Strobe - 15-95 multi-cd, FIRE marking, mounts to 4 inch square x 2-1/8 inch box. SD-TRK SD Remote Reset/Test, 2W/SIG. SD-TRK4 Duct Detector Accessory, Remote Test/Reset Station/Key.
SIGA-270 Manual Pull Station - Single Action, 1-stage. SIGA-278 Manual Pull Station - Double Action, 1-stage. SIGA-CC1 Single Input (Riser) Module.
Features a built-in RING TONE generator; use for switching a single signal or audio circuit. SIGA-CC1S Single Input (Riser) Module with strobe synchronization output. SIGA-CT1 Single Input Module.
Single circuit input module for use with Normally Open Contact devices. Four selectable personality codes for Alarm latching, or Alarm Delayed latching, or non-latching monitor or latching supervisory. SIGA-CT2 Dual Input Module. Two circuit input module for use with Normally Open Contact devices. Four selectable personality codes (on each circuit) for Alarm latching, or Alarm Delayed latching, or non-latching monitor or latching supervisory. SIGA-LED Remote Alarm LED.
Use with -SB and -SB4 Standard Base only. SIGA-PS Intelligent Photoelectric Smoke Detector. SIGA2-PS Intelligent Second Generation Photoelectric Smoke Detector. SIGA-SD SuperDuct, Signature Series duct smoke detector.
SIGA2-HFS Intelligent Second Generation Fixed Temperature Heat Detector - 135F. SIGA2-HRS Intelligent Second Generation Fixed Temperature / Rate-of-Rise Heat Detector - 135F, 15F per minute.
Global leader in fire alarm, mass notification and hazard warning. Whether Edwards™ detection and alarm solutions are protecting the lives and livelihoods of the people who make businesses run, or who receive treatment at healthcare institutions; whether they’re charged with protecting students, staff and faculty at the world’s finest universities, or preserving irreplaceable artifacts that bring humankind’s history to life; Edwards finds innovative ways to meet site-specific challenges and make every project a success. Edwards' solutions are modular, scalable, and meet the needs of applications ranging from fire detection to industrial signaling and mass notification – all technologically advanced innovations that deliver value and reliability for the entire service life of the product. When facility owners and designers do business with Edwards, their investment is underwritten by a history of excellence and ingenuity that dates back over 140 years.