Onan Generator Manual Bgm

Posted on by admin

Repair manual Cummins Onan BGM is a repair guide, which contains a detailed service information, operating instructions and maintenance, special instructions for repair and maintenance, parts manuals, service documentation and any additional information that is presented specifically for the maintenance of equipment Cummins. Workshop repair manual Cummins Onan BGM contains detailed diagrams and charts that help to carry out installation or removal of any parts Cummins Onan. Electronic product Cummins Onan BGM is designed to run on a PC, has been tested using Microsoft Internet Explorer. E-program Cummins Onan BGM works with both disk and a full installation on a hard disk. By setting the manual Cummins Onan BGM user can find the results of all tests and inspections loaders. Service manual Cummins Onan BGM is a system of care in operation and maintenance of equipment Cummins Onan, which allows you to perform diagnostic tests, identify and resolve your problem and inaccuracies.

  1. Onan Generator Manual Microquiet 4000
  2. Onan Generator Manual Model Cck

Screenshots for Cummins Onan BGM Service Repair Parts Manuals.

. BGM, NHM Printed in U.S.A. 8−95 965−0136.

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Redistribution or publication of this document, by any means, is strictly prohibited.Cleaning The Carburetor And Combustion Chambers With Onan “4C”.

Onan Generator Manual Microquiet 4000

Safety Precautions Thoroughly read the OPERATOR’S MANUAL Use caution when making adjustments while the genset is running—hot, moving or electri- before operating the genset. Safe operation and cally live parts can cause severe personal inju- top performance can be obtained only with ry or death.

FUEL IS FLAMMABLE AND EXPLOSIVE MOVING PARTS CAN CAUSE SEVERE PERSONAL INJURY OR DEATH Keep flames, cigarettes, sparks, pilot lights, electrical arc-producing equipment switches and all other sources of ignition well Do not wear loose clothing or jewelry near mov- away from areas where fuel fumes are present ing parts such as PTO shafts, fans, belts and and areas sharing ventilation. Introduction ABOUT THIS MANUAL This manual covers the operation and maintenance of the the Marquis BGM and NHM series of gener- ator sets (gensets). Study this manual carefully and observe all of its instructions and precautions.

Component Locations, Starting and Stopping, Pow- ering Equipment and Varying Operating Conditions cover basic operation of the genset. FUEL RECOMMENDATIONS ENGINE OIL RECOMMENDATIONS Gasoline and LPG are highly flam- WARNING Use premium quality motor oil. Look for the API mable fuels and can cause severe personal inju- (American Petroleum Institute) classification and ry or death. Do not smoke if you smell gas or use Class SG or SH oil (also SG/CD, SG/CE, SH/ gasoline or are near fuel tanks or fuel-burning CD or SH/CE).

Onan Generator Manual Model Cck

Component Locations COMPONENTS REQUIRING PERIODIC Maintenance ) are located as shown in Figure 2. The genset itself is usually located behind a door in a ATTENTION OR MAINTENANCE compartment somewhere around the perimeter of The control panel and the components requiring the vehicle. GENSET CONTROL PANEL CONTROL LINE CIRCUIT FUSE F1 BREAKERS The genset control panel (Figure 3) and box include the following features: START-STOP Switch - This is a rocker switch which returns to its neutral position when you let go. Hold it in the START position to crank and start the genset and push it momentarily to the STOP posi- tion to stop the genset. There may also be an enable switch in the cab or other space which can be locked to prevent unauthorized operation of the genset. Onan offers optional remote control kits that can be connected to the genset.

There are three models available: Remote panel with start/stop switch and indica- tor lamp only (see Figure 4). Starting and Stopping EXHAUST GAS IS DEADLY! WARNING Exhaust gases contain carbon monoxide, an odorless and colorless gas. Carbon monoxide is poi- sonous and can cause unconsciousness and death.

Symptoms of carbon monoxide poisoning in- clude: Dizziness Throbbing in Temples Nausea Muscular Twitching Headache. Powering Equipment TABLE 2. TYPICAL APPLIANCE POWER GENSET LOADING CONSUMPTION The AC output of the genset powers the vehicle air Power Consumption conditioner, the DC converter/battery charger and Appliance (watts) the appliances that may be plugged into the electri- Air Conditioner 1400-2000 cal outlets of the vehicle. RESETTING CIRCUIT BREAKERS Interconnecting the genset and the WARNING public utility (or any other power source) can If a circuit breaker in the main power distribution lead to the electrocution of personnel working panel of the vehicle or on the genset (Figure 7) trips, on the utility lines, damage to equipment and there is either a short circuit or too many appliances fire.

Varying Operating Conditions 5. At temperatures above 70 F (21 C) push the COLD WEATHER carburetor preheater lever up to the SUMMER Pay particular attention to the following items when position (gasoline models only). The lever is lo- operating the genset in cold weather: cated on the front of the air cleaner (Figure 8). HIGH ALTITUDE For best fuel economy and genset operation set the carburetor altitude adjust knob (Figure 9) for your al- titude (gasoline models only). Look at road maps, travel atlases and road signs for altitude. (See Pow- ering Equipment for information on how altitude af- fects the maximum power output of the genset.) Operating the genset at low altitude CAUTION. 4 - Perform at least once a year.

5 - Perform sooner if engine performance deteriorates. 6 - Must be performed by a qualified mechanic (authorized Onan dealer).

OnanGenerator

Redistribution or publication of this document, by any means, is strictly prohibited. OIL LEVEL CHECK AND GENERAL for LPG leaks.

Check flexible fuel hose sections for cuts, cracks, and abrasions. Make sure the fuel line INSPECTION is not rubbing against other parts. Replace worn or Inspect the genset before the first start of the day damaged fuel line parts before leaks occur. Clean accumulated dust and dirt from the genset. Do not clean the genset while it is running or still hot. Protect the generator, air cleaner, control panel, and OIL FILL CAP AND DIPSTICK electrical connections from water, soap and clean- ing solvents. Refill with API Class SG or SH oil (also SG/CD, CHANGING ENGINE OIL AND OIL FILTER SG/CE, SH/CD or SH/CE) having an SAE vis- Refer to Table 4 for scheduled engine oil change.

In cosity grade appropriate for the expected tem- hot weather and dusty conditions the oil should be peratures, as indicated in Table 1. BATTERY CARE 5. If the battery is not of the “maintenance-free” type, maintain the electrolyte level by adding Refer to Table 4 for scheduled battery maintenance distilled water. Fill each cell to the split-level and to the battery manufacturer’s recommenda- marker in the battery. AIR FILTER Refer to Table 4 for scheduled air filter replacement.

In dusty conditions the air filter element and wrapper should be inspected and changed more frequently for best operation. To change the air filter element and wrapper, re- move the through-bolt and cover (Figure 13).

Re- assemble the air filter with a new air filter element and wrapper. (see Powering Equipment). Let the genset AND COMBUSTION CHAMBERS WITH run for about five minutes to expel the carbon ONAN “4C” loosened by the cleaner. Refer to Table 4 for scheduled cleaning of the carbu- retor and combustion chambers. It is important to. Suzuki quad sport 50 manual. Genset Break-In, Exercise and Storage first 24 hours of operation and change the oil after BREAK-IN the first 50 hours of operation. Proper engine break-in on a new genset or on one with a rebuilt engine is essential for top engine per- EXERCISE formance and acceptable oil consumption.

7) when the genset is ready to power ap- turer’s recommendations. OnaFresh and OnaGard are trademarks of the Onan Corporation. Redistribution or publication of this document, by any means, is strictly prohibited. Review the safety precautions on the Onan dealer.

See How to Obtain Service. Inside cover page. Many troubleshooting procedures Hot engine parts can cause severe.